Beckhoff CX1020 Instrukcja Użytkownika Strona 71

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 123
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 70
Assembly and connecting
Embedded PC 69
Correct installation position:
The high-performance CX1020 system generates a significant amount of heat, which is dissipated via a passive
ventilation system. This system requires the unit to be mounted correctly. Ventilation openings are located at the top
and bottom of the housing. The system therefore has to be installed horizontally. This ensures optimum air flow.
Incorrect installation positions:
The CX1020 system must not be operated vertically on the top-hat rail. A vertical position would lead to insufficient
CPU ventilation, since the ventilation openings are located on the top and bottom of the housing. Installation of the
system on its side would also lead to inadequate ventilation.
Przeglądanie stron 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 ... 122 123

Komentarze do niniejszej Instrukcji

Brak uwag