Podsumowanie treści

Strona 1 - Hardware documentation

CX1000 Embedded PC Hardware documentation CX1000-0xxx CX1000-Nxxxversion: 1.1date: 2006-06-21

Strona 2

Product Overview8 Embedded PCSystem interfacesFurther system interfaces for serial communication(2x RS 232, and RS422, RS485) as well as audio signals

Strona 3 - Table of contents

Product OverviewEmbedded PC 9Base ModulesTechnical DataThe CX1000 CPU module is the basic module of the CX system. It comprises the CPU and the intern

Strona 4 - 7. Appendix 46

Product Overview10 Embedded PCTypesThe CPU module can be equipped with different hardware and software options: the internal memory is expandable to 3

Strona 5 - 1. Foreword

Product OverviewEmbedded PC 11CX1001-0112* * * *CX1001-0120* * * *CX1001-0121* * * *CX1001-0122* * * *CX1000 systems with Windows XP Embedded require

Strona 6 - Description of safety symbols

Product Overview12 Embedded PCConnectionsThe basic CPU module is available with different hardware and software options. It is supplied from the power

Strona 7 - Documentation Issue Status

Product OverviewEmbedded PC 13Basic CPU module with DVI/USB interface:In addition to the Ethernet and COM interface, this basic module features a DVI-

Strona 8 - 2. Product Overview

Product Overview14 Embedded PCCompact Flash slotA Compact Flash slot is provided at the front of the basic CPU module. This enables an additional Comp

Strona 9 - System Overview

Product OverviewEmbedded PC 15PC 104 BusThe PC 104 bus is a standerdised bus with 104ISA signals for compact embedded systems.For the functionality of

Strona 10 - The Software

Product Overview16 Embedded PCRemarks:2. B10 and C19 are key locations. 3. Signal timing and function are as specified in ISA specification. 4. Signal

Strona 11 - Base Modules

Product OverviewEmbedded PC 17System interfacesTechnical DataUnlike other CX components, the system interfaces cannot be upgraded or expanded in the f

Strona 13 - Embedded PC 11

Product Overview18 Embedded PCCX1000-N001 connectionsIn addition to the Ethernet and RS232 interface, this module features a DVI-I and two USB interfa

Strona 14 - Connections

Product OverviewEmbedded PC 19USB interface:The USB socket is a type A socket. The USB interface complies to USB 1.1 specificationPin Assignment Typic

Strona 15 - Embedded PC 13

Product Overview20 Embedded PCCX1000-N002 connectionsThe CX1000-N002 system interface features two RS232 interfaces, COM2 and COM3 (9 pin Sub-D plug c

Strona 16 - Compact-Flash card

Product OverviewEmbedded PC 21CX1000-N003 connectionsThis system interface contains the audio interfaces Line In, Mic In (microphone signal input) and

Strona 17 - PC 104 Bus

Product Overview22 Embedded PCCX1000-N005 connectionsThe system interface CX1000-N005 contains two RS422, RS485 interfaces, COM2 and COM3 (9 pin Sub-D

Strona 18 - 16 Embedded PC

Product OverviewEmbedded PC 23RS485 without Echo, Drop-Point ( without Termination)DIP Status Function1 off Echo on2 on Echo off3 on Auto send on4 off

Strona 19 - System interfaces

Product Overview24 Embedded PCPower supplyTechnical Data CX1100-0001One of three power supply modules can be selected for a CX1000 system. The power s

Strona 20 - CX1000-N001 connections

Product OverviewEmbedded PC 25Technical Data CX1100-0002 / CX1100-0003Local I/O signals are connected via the CX1100-0002 power supply variant, to whi

Strona 21 - Embedded PC 19

Product Overview26 Embedded PCCX1100-0001 ConnectionsThis power supply unit does not have an I/O interface. The power supply is therefore connected th

Strona 22 - CX1000-N002 connections

Product OverviewEmbedded PC 27CX1100-0002 ConnectionsThis power supply unit is equipped with an I/O interface, which permits connection of the Beckhof

Strona 23 - CX1000-N003 connections

Table of contentsEmbedded PC 1Table of contentsCX1000 Hardware Documentation1. ForewordNotes on the ManualSafety instructions 4Documentation Issue Sta

Strona 24 - CX1000-N005 connections

Product Overview28 Embedded PCCX1100-0003 ConnectionsThis power supply unit permits not only the connection of the Beckhoff Bus Terminals, but also th

Strona 25 - Settings DIP Switches RS422:

Product OverviewEmbedded PC 29LCD DisplayThe LCD display of the power supply units has two rows of 16 characters each and is used for displaying syste

Strona 26 - Power supply

Transport30 Embedded PC3. TransportUnpacking, installation and transportThe specified storage conditions must be adhered to (see "Technical data&

Strona 27 - Embedded PC 25

Fitting and wiringEmbedded PC 314. Fitting and wiringMechanical mountingDimensionsThe CX1000 product range is characterised by small overall installed

Strona 28 - CX1100-0001 Connections

Fitting and wiring32 Embedded PCMechanical Assembly of the base moduleThe installation of the modules takes place in three steps:1. The Sequence of th

Strona 29 - CX1100-0002 Connections

Fitting and wiringEmbedded PC 33FIG. 6: Tension straps back in starting position FIG.7: Tension straps not engaged / engagedNote:A locking mechanism p

Strona 30 - CX1100-0003 Connections

Fitting and wiring34 Embedded PCFIG. 9: Allowable installation positionFIG. 10: Unallowable installation position

Strona 31 - LCD Display

Fitting and wiringEmbedded PC 35Mechanical mounting of the Fieldbus modulesThe mounting of the Fieldbus modules takes place in several steps:1. Remove

Strona 32 - 3. Transport

Fitting and wiring36 Embedded PCFIG. 4: Tension straps back in starting position3. Attach CoverIf the connection area does not have a closing cover on

Strona 33 - 4. Fitting and wiring

Error handling and diagnosticsEmbedded PC 375. Error handling and diagnosticsCPU base moduleLEDs of the basic CPU moduleDisplay LED MeaningPWR Power s

Strona 34 - 32 Embedded PC

Table of contents2 Embedded PCPower supplys 38LED CX1100-0001 38LED CX1100-0002 39LED CX1100-0003 41Trouble shooting 436. Decommissioning 44Removal an

Strona 35 - Observe minimum clearance!

Error handling and diagnostics38 Embedded PCPower supplysCX1100-0001 power supply LEDsDisplay LED MeaningPower Power supply The LED lights up green wh

Strona 36 - 34 Embedded PC

Error handling and diagnosticsEmbedded PC 39CX1100-0002 power supply LEDsAfter switching on, the power supply immediately checks the connected Bus Ter

Strona 37 - Embedded PC 35

Error handling and diagnostics40 Embedded PCconsistent with the configuration that existed when the boot project was createdclear the boot project.14

Strona 38 - 3. Attach Cover

Error handling and diagnosticsEmbedded PC 41CX1100-0003 power supply LEDsAfter switching on, the power supply immediately checks the connected Bus Ter

Strona 39 - CPU base module

Error handling and diagnostics42 Embedded PCconsistent with the configuration that existed when the boot project was createdclear the boot project.14

Strona 40 - Power supplys

Error handling and diagnosticsEmbedded PC 43StörungenLesen Sie dazu auch das Kapitel Sicherheitshinweise.Mögliche Störungen und ihre BeseitigungBitte

Strona 41 - LEDs for K-Bus diagnosis

Decommissioning44 Embedded PC6. DecommissioningRemoval and disposalA CX1000 hardware configuration is dismantled in 2 stages:1. Removing from the top-

Strona 42 - 40 Embedded PC

DecommissioningEmbedded PC 45FIG. 4: Undoing the latching mechanism FIG 5: Separating the modulesThe CPU can be separated from the power supply unit

Strona 43

Appendix46 Embedded PC7. AppendixAccessoriesCompact flash cardsorder number DescriptionCX1900-0015 128 MByte compact flash card type ICX1900-0017 256

Strona 44 - 42 Embedded PC

AppendixEmbedded PC 47Support and ServiceBeckhoff and their partners around the world offer comprehensive support and service, making available fast a

Strona 45 - Störungen

ForewordEmbedded PC 31. ForewordNotes on the ManualThis description is only intended for the use of trained specialists in control and automation engi

Strona 46 - 6. Decommissioning

Appendix48 Embedded PCCertificationsAll products of the Embedded PC family are CE, UL and GOST-R certified. Since the product family is continuously d

Strona 47 - Disposal

Foreword4 Embedded PCSafety InstructionsSafety RulesThe responsible staff must ensure that the application or use of the products described satisfy al

Strona 48 - 7. Appendix

ForewordEmbedded PC 5Documentation Issue StatusVersion Changes1.1 comments on hardware watchdog added1.0 updated version0.1 preliminarily version

Strona 49 - Beckhoff Headquarters

Product Overview6 Embedded PC2. Product OverviewAppropriate UseThe CX1000 device series is a modular control system that can be mounted on top hat rai

Strona 50 - Certifications

Product OverviewEmbedded PC 7System OverviewThe System The CX1000 system covers the whole range of Beckhoff control technology both in terms of price