Page 22 of 44 Version : 2.01 Date : 18.12.95
Funktion 07
h
: Address test
This function is used to prove if the modules still hold the address, they received
when they were initialized.
channel length function argument
0
argument
1
argument
2
comment
call
02 07
response
04 07 00 00
addresses correct
04 07 01 nn
error at address nn
In order to keep a maximum of safety for the system, this function is even run
resident when the system is working normally. In case an error is detected a
message is transmitted through the GCB to the VME system.