Eiserstraße 5 / D-33415 Verl / Telefon 05246/963-0 / Telefax 05246/963-149
FC520x / CX1500-x520 14
BECKHOFF FC520x / CX1500-x520
3 Fitting and Wiring
3.1 Installation
3.1.1 FC520x
Note:
Fieldbus PCI cards may only be fitted by qualified personnel in accordance and the following points
must be observed
In order to protect the card from electrostatic discharge the user must be discharged before han-
dling the card or the PC.
Before opening the PC housing it must be switched off, and the mains plug must be removed.
It may be necessary before fitting to set the Dip-Switch in order to activate the internal CAN / DeviceNet
bus terminating resistors. The card can be fitted into any free PCI slot. Ensure that the PCI bus connector
is making good contact, and that the module is seated firmly. Fasten the module to the PC slot housing
with the fixing screw.
DIP-Switch for terminating resistor (120 Ohm) for
each channel
Devic
Net
Channel B
Devic
Net
Channel A
B
A