Beckhoff FM33xx Instrukcja Użytkownika Strona 30

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 39
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 29
I/O configuration
FM33xx 25
Multiplex mode channel data in the
TwinCAT System Manager
The channel data of a TC-Plug module is mapped and displayed as follows
in the TwinCAT System Manager, independently of the number of channels
that are configured (associated):
Process data for the TC-
Plug modules in the
TwinCAT System Manager
Control/status byte and
channel data for the 4
thermocouple inputs
In order to reduce the quantity of data that has to be transferred over the
fieldbus, the thermocouple input data for a maximum of 4 channels only
(e.g. for channels 0 to 3) is transferred over the fieldbus in any one fieldbus
cycle. The control/status byte can be used to request the analog values of
another 4 channels (e.g. for channels 4 to 7, 8 to 11 etc.).
Control/status
byte
Channel
data
Przeglądanie stron 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 38 39

Komentarze do niniejszej Instrukcji

Brak uwag