Beckhoff CX2100­09x4 Instrukcja Użytkownika Strona 73

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 87
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 72
Commissioning
Statusinfo Beckhoff
P24VxxxxUPS
Beckhoff24V
UPScon
nectedto
CP903xISAor
PCIcard
APCBackUPS
Pro280
APCSmart
UPS420
Description
hardware
revision
required!
Battery
replace
service
intervall
has
expired
(bit10is
set).
Implement
edinUPS
Software
version>=
3.0.0.8;
*)Onlyavailableifmodel"SmartSignalingtoanyAPCUPS&TwinCAT"configured!
Requirements
Developmentenviron
ment
Targetsystemtype UPShardware PLClibrariestoinclude
TwinCATv2.8.0,Build>
745TwinCATv2.9.0,
Build>945
PC(i386) BeckhoffP24Vxxxx
USV;
IntegratedBeckhoff
IndustrialPC24V
UPSconnectedto
CP903xISAorPCI
card;
WithBeckhoff
IndustrialPC's
deliveredAPCUPS
modelssupporting
smartprotocoland
configuredwith
WindowsUPS
Service;
TcIoFunctions.Lib
(Standard.Lib;
TcBase.Lib;
TcSystem.Lib;
TcUtilities.Libareincluded
automatically)
5.3.3 TYPEE_BatteryStatus
TYPEE_BatteryStatus:
(
BatteryUnknownStatus,(*Thebatterystatusisunknown.*)
BatteryOk,(*ThebatteriesareOK.*)
BatteryReplace(*Thebatteriesneedtobereplaced.*)
END_TYPE
CX210009x4 73Version1.1
Przeglądanie stron 72
1 2 ... 68 69 70 71 72 73 74 75 76 77 78 ... 86 87

Komentarze do niniejszej Instrukcji

Brak uwag