SIDNs
S00170Probingcycleprocedurecommand(pc)
Theparametercontainsthecommandmeasuringprobecycle.Ifthemastersetsandactivatesthis
command,thedriverespondstoS00405,asspecifiedinS00169.The"probeunit"isactivated.
Attributes
Name Value
Format binary
Datalength 16
Decimalpoint 0
Minvalue
Maxvalue
Defaultvalue
Unit
ChangeableinEtherCATstate SafeOp,Op
Cyclictransfer No
Deviceparameter No
Relatedtointerfacerevision
IfS00170isactivated,thecontrollercanstartnumerousmeasurements.Thiscommandshouldbestopped
assoonasthecontrollerhascompletedthemeasurements.
Bitpattern:
Bit Meaning
0 Cancelcmd
Cancelcommand
0=disable
1=enable
1 Setcmd
Setcommand
0=disable
1=enable
2 Reserved
3 Set&enablecommand
Set&enablecommand
0=disable
1=enable
4
15
Reserved
Note
IDNsinvolved
S‐0‐0169 [}122],S‐0‐0405 [}173]
AX5000IDNDescriptions124 Version3.1